AVENTICS | AES | R412018134–BAL–001–AD/06.2016 | English
Responsibilities of the system owner
As the operator of a system that will be equipped with modules
from the AES series, you are responsible for
W
ensuring intended use,
W
ensuring that operating employees receive regular instruction,
W
ensuring that the operating conditions are in line with the
requirements for the safe use of the product,
W
ensuring that cleaning intervals are determined and complied
with according to environmental stress factors at the
operating site,
W
ensuring the observance of ignition hazards that develop due
to the installation of system equipment,
W
ensuring that no unauthorized repairs are attempted if there is
a malfunction.
3
General Instructions on
Equipment and Product Damage
Mechanical loads!
Damage to the module!
O
Make sure that the module is not under mechanical strain,
e.g. stress caused by fastening the unit to the mounting
surface.
O
During and after assembly, make sure that the entire unit is
supported at intervals of max. 150 mm to prevent bending
or deformation.
O
Use retaining brackets to mount the device to the mounting
surface when assembling more than three I/O modules.
Loss of the IP protection class if the spring clamp elements
are bent!
O
Always pull the spring clamp elements up to the stop before
combining the modules.
4

Delivery Contents

W
1 bus coupler or I/O module from series AES
W
For the bus coupler: 3 mounting screws
W
For I/O modules: 2 spring clamp elements
W
1 CD (R412018133)
W
1 set of assembly instructions R412018134
5

About This Product

The bus coupler and I/O modules are available in different
versions. The pin assignments may deviate from the figures.
NOTICE
NOTICE
Valve system, series AV
1
Left end plate
2
I/O modules, series AES
3
Bus coupler, series AES
4
Transition plate
5
Pneumatic unit, series AV
6
Electrical unit, series AES
7
Retaining bracket
8
Recess for retaining bracket
9
Rating plate with configuration key
AES unit as stand-alone variant
1
Left end plate
2
I/O modules, series AES
3
Bus coupler, series AES
4
Right end plate for stand-alone variant
5
Rating plate
Bus coupler
3
1
Identification key
2
LEDs (see system manual for description)
3
Window
4
Field for equipment ID
5
Fieldbus connection (see system manual)
6
Fieldbus connection (see system manual)
7
Power supply connection X1S
8
Functional earth
9
Base for spring clamp element mounting
10 Mounting screws for fastening to the transition plate
11 Electrical connection for AES modules
12 Rating plate
13 Electrical connection for AV modules
Input module/output module
1
PLC configuration key
2
LEDs (see system manual for description)
3
LED for output or input signals
4
Field for equipment ID
5
Slot for spring clamp element mounting
6
Field for channel and plug labeling
7
Auxiliary power supply connection (optionally available)
8
Functional earth (optionally available)
9
Base for spring clamp element mounting
10 Signal input/output
11 Electrical connection for AES modules
12 Rating plate
13 Recess for retaining bracket
Product identification
You can find information on the PLC configuration key in the
system description for the module.
For information on the rating plate, see
The rating plate shown here is an example.
O
Check the part number on the rating plate to determine
whether the module matches your order.
1
2
4
.