7

Commissioning and Operation

Danger of explosion with no impact protection!
Mechanical damage, e.g. strain on the push-in fittings or plug
connectors, will lead to non-compliance with the IP65/IP67
protection class.
O
In explosive environments, make sure that the devices is
installed in a manner that protects it from all types of
mechanical damage.
Danger of explosion due to damaged housing!
Damaged housing can lead to an explosion in explosive areas.
O
Make sure that the valve system components are only
operated with completely assembled and intact housing.
Danger of explosion due to missing seals and plugs!
Liquids and foreign objects could penetrate and destroy the
device.
O
Make sure that the seals are integrated in the plug and not
damaged.
O
Make sure that all plugs are mounted before starting the
system.
Information on settings and adjustments can be found in the
system descriptions on the enclosed CD (R412018133).
O
Always observe the system documentation when
commissioning the relevant system component.
8
Disposal
O
Dispose of the module in accordance with your country's
national regulations.
DANGER
9

Technical data

General data
Dimensions
Bus coupler: 37.5 mm x 52 mm x 102 mm
W x H x D
I/O module: 50 mm x 34 mm x 82 mm
Weight
Bus coupler: 0.160–0.175 kg with mounting
screws, depending on the fieldbus
I/O module: 0.11 kg
Temperature
-10°C to 60°C
range
Application
Temperature
-25°C to 80°C
range
Storage
Mounting ori-
Any
entation
Power supply
Bus coupler:
Electronics: 24 V DC ±25%
Valves: 24 V DC ±10%
Only use a power pack with safe isolation for
the power supply.
I/O module: through the bus coupler via the
backplane
Protection
IP65/IP67 (only when assembled and with all
class acc. to
plugs mounted)
EN 60529/
IEC529
O
Further technical data for your configuration can be found on
the rating plate and in the pages of the online product catalog
from AVENTICS.
10 Accessories
Designation
Retaining bracket, 10x
Spring clamp element, 10x, including as-
sembly instructions
Left end plate
Right end plate for stand-alone variant
12
Part number
R412018339
R412015400
R412015398
R412015741