ENGLISH
3) Soak a clean cloth with the neutral cleaner, and wipe both sides of the slope and the door inner surface. Wipe off the cleaner
with a clean damp cloth.
4) Either mix 5 litres of water with 18 ml of 5.25% sodium hypochlorite solution in a suitable container, or the recommended
Hoshizaki sanitiser as directed.
5) Soak a clean sponge or cloth with the solution, and wipe the bin liner, bin door and slope.
6) The remaining solution can be used to sanitise utensils.
Note: Do not wipe dry or rinse after sanitising, but allow to air dry.
[d] Air Filter (Air-Cooled Model Only)
Plastic mesh air filters remove dirt or dust from the air, and keep the condenser from getting clogged. If the filters get clogged,
the icemaker's performance will be reduced. Remove and clean the air filter(s) at least twice per month:
1) Slide the air filter off the filter guide [IM-21CNE/30CNE] or the louver [IM-45CNE/45NE/65NE/100CNE/100NE/130NE/240NE].
2) Clean the air filter by using a vacuum cleaner. When severely clogged, use warm water and a neutral cleaner to wash the air
filter.
3) Rinse and dry the air filter thoroughly.
After cleaning, be sure to place the air filter back in position.
Air Filter
[IM-21CNE/30CNE]
2. BEFORE CALLING FOR SERVICE
[a] Error Code Indication
If the error code "E" is indicated on the display, before calling for service, check the following.
Code
E1
Freeze error. Unplug unit and plug it back in after 3 minutes. Clean air filter (air-cooled model). Lower ambient
temperature or ensure adequate clearance around unit (see "I. 4. LOCATION"). If error persists, call for service.
E2
Defrost error. Unplug unit and plug it back in after 3 minutes. If error persists, call for service.
EE
Other error. Unplug unit and plug it back in after 3 minutes. Clean air filter (air-cooled model). Check for water
failure or closed water supply tap. Lower ambient temperature or ensure adequate clearance around unit (see "I. 4.
LOCATION"). If error persists, call for service.
NOTICE
Filter Guide
Slide in/out
[IM-45CNE/45NE/65NE/100NE/130NE/240NE]
WARNING
Do not damage the refrigerant circuit.
Remedy
10
Air Filter
Louver
* Figure shows IM-240NE
Air Filter
Louver
[IM-100CNE]