10) Refit the two caps on the cleaning outlets to seal them off.
11) Slide the spray assembly along the rails on the right and left brackets. Refit the
discharge tube securely on the spray outlet. A loose fitting may cause a water leak.
12) Position and lock the ice chute on to the front and rear frame pipes by pushing the chute down
until it clicks on to both pipes.
13) Slide in the water tank along the rails at the bottom of the right and left brackets until
it clicks into place.
14) Refit the water pipe securely in the arrow direction. A loose fitting may cause a water leak.
15) Hook each separator on to the rail, and pull it hard toward you until it locks in place with a click.
Refit all the separators in the same way.
16) Check for water leaks and proper ice production.
17) Follow the steps in "II. 1. START UP".

2. BEFORE CALLING FOR SERVICE

If the icemaker does not work properly or does not work at all, then before calling for service, check that:
* The power is supplied to the unit.
* The water is turned on.
For further assistance or advice, contact your local Hoshizaki service agent.
WARNING
Do not damage the refrigerant circuit.