Fabrication Nº:
Equipment:
OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL
6
TEHCNICAL CHARACTERISTICS OF SKID FOR TEMPERATURE CONTROL
6.1 GENERAL DESCRIPTION OF SKID
With the VCR vessel and MET tank is also supplied a skid which integrates all the
valves, pneumatic actuators and accessories needed for the cooling and heating
process.
Skid consists in a stainless steel structure of 1050x520x1682 mm (Length x Width x
Height) and has the following connections:
-
SKID Chilled water outlet
-
SKID Chilled water inlet
-
SKID Steam inlet
-
SKID Drain outlet
-
MET Steam outlet
-
VCR Steam outlet/SKID Chilled Water Inlet
-
SKID Condensates outlet
-
MET Steam inlet
-
VCR Steam Inlet/SKID Chilled Water Outlet
Valves control is performed by a PLC and a touch screen and for the temperature
regulation in heating process there are pneumatic regulation valves (4-20 mA).
The skid has also a compressed air inlet in order to ensure the properly drainage of
the piping.
Ref. ProJect / Revision:
721021-07 / R01
721021-70-1 / 721021-70-3
VESSEL FOR CREAMS – Mod. VCR 1002 / MELT TANK – Mod. MET 0400
Client:
UNIPHARMA
Date:
11-2015
EN
ES
MDI VCR (v1.0)
29 of 153