Care And Maintenance; Maintenance Schedule - Kärcher HDS 9/14-4 ST Manual Original

Ocultar thumbs Ver también para HDS 9/14-4 ST:
Tabla de contenido

Publicidad

DANGER
Risk of injury! The main switch of the vacuum cleaner is to be switched off or the Cekon plug must be unplugged while carrying out
any repairs or maintenance jobs.
Time
Activity
daily
Check hand-
spray gun
Check high pres-
sure hoses
Check the con-
necting line with
mains plug
weekly or after 40
Check oil level
operating hours
Check oil level
Cleaning the
sieve
monthly or after
Clean and check
200 operating
the ignition elec-
hours
trodes
Check pump
Check for inter-
nal deposits
Cleaning the
sieve
half-yearly or after
Oil change
1000 operating
hours
check, clean
annual
Safety check
at least every 5
Pressure test
years, recurring
30

Care and maintenance

Maintenance schedule

Assembly affected
Hand spray gun
Outlets, hoses towards working
machine
Electrical connection with plug/
socket
Oil tank at the pump
Oil tank at the pump
Sieve in water inlet
Ignition electrodes located in
the lid of the continuous heater
High-pressure pump
Entire plant
Sieve in the water shortage
safeguard
High-pressure pump
Entire plant
Entire plant
Entire plant
EN
Performance
Check whether the hand-spray gun closes tightly
without any leaks. Check the protection mecha-
nism against accidental switching. Replace de-
fective hand-spray guns.
Check hoses to see if there are damages. Re-
place defect hoses immediately. Danger of acci-
dent!
Check the connecting line with mains plug for
damages. If the power cord is damaged, please
arrange immediately for the exchange by an au-
thorized customer service or a skilled electrician.
If the oil is milky, it needs to be replaced.
Check oil level of the pump. Refill oil if required
(Order no. 6.288-016)
See section "Clean sieve".
Unscrew the fuel pipe, dismantle the electrode
holder and clean the electrodes. Check the elec-
trode setting according to the diagram on the fol-
lowing page and make the necessary adjust-
ments.
Check the pump for leaks. If the leakage is more
than 3 drops per minute, call Customer Service.
Operate the machine using the spray pipe without
the high pressure nozzle. If the operating pres-
sure on the manometer of the machine increases
to more than 3 MPa, then the plant needs to be
decalcified. The same is applicable when an op-
erating pressure of more than 0.7 - 1 MPa is de-
tected while operating the machine without high
pressure pipe (water comes out freely at the high
pressure outlet).
See section "Clean sieve".
Drain off oil. Fill in 1 l new oil (Order no. 6.288-
016). Check oil level in the oil tank.
Visual inspection of the plant, check high pres-
sure connections to see that they are not leaking,
check that the over-flow valves are not leaking,
check high pressure hoses, pressure tanks,
clean/ replace fuel filters, remove the rust/ calci-
um deposits from the heating coil, clean/ replace
ignition electrodes, clean/ replace burner nozzle,
adjust burner.
Perform a safety inspection as per the applicable
national rules and regulations for liquid spray jets
of the respective country.
Perform the pressure test as per manufacturer's
instructions.
9
-
of whom
Operator
Operator
Operator
Operator
Operator
Operator
Trained oper-
ator
Operator
Operator
trained in de-
calcification
Operator
Operator
Customer
Service
Technical ex-
pert
Technical ex-
pert