Factory settings
– Twilight setting: daylight mode 1,000 lux
– Time setting: 2 seconds
– Reach setting: 5 metres
Twilight setting
The response threshold (twilight) can be infinitely varied
from approx. 2-2,000 lux.
= daylight mode (depending on ambient light level)
= night-time operation (approx. 2 lux)
The control dial must be turned to daylight mode when
adjusting the detection zone and performing the functional
test in daylight..
Time setting
The stay-ON time can be set to any period from approx.
5 seconds to a maximum of 60 minutes. Every movement
detected re-activates the light.
Note: after the LED light switches OFF, it takes approx.
1 second before movement can detected again. The LED
light can then switch ON again in response to movement.
The shortest time setting is recommended when adjusting
the detection zone and performing the
functional test.
Reach setting (sensitivity)
Reach is the term used to describe the diameter of the
more or less circular detection zone produced on the
ground after mounting the SensorLight at a height of 2 m.
– Set to maximum = max. reach (5 m)
– Set to minimum = min. reach (1 m)