5.15 PSA 55 infrared adapter

5.15.1 Before first use

Note
Install the Hilti PROFIS Detection PC application on your PC or laptop. The date and time must be set
before using the PSA 55 IR adapter for the first time in order to ensure that the scan data subsequently
shows the correct date and time.
To do this, use the PUA 95 Micro USB cable to connect the PSA 55 IR adapter to the computer.
Open the Hilti PROFIS Detection PC application.
Go to "Tools", "Workflow" and then select "Set PSA 55 date and time". The date and time are then set
in the PSA 55 IR adapter.
Note
The device driver will be installed together with Hilti PROFIS Detection. If this is not the case, the
device driver must be installed manually by running the "setup.exe" file located in the "Drivers" folder
on the PSA 55 IR adapter.
5.15.2 Operating the PSA 55 infrared adapter
The scans can be transferred to the adapter via the infrared interface and from there to the PC or laptop.
Switch the adapter on or off by pressing the on / off button for about 3 seconds.
The LED display on the adapter can indicate the following statuses:
The green LED lights constantly: The adapter is switched on and is ready for operation.
The red LED flashes rapidly: Battery state of charge is low.
The green LED flashes: The adapter has just been switched on.
The green LED flashes: Data transfer in progress.
The red LED flashes and the adapter switches itself off: Memory is 95% full.

5.16 Data transfer

5.16.1 Data transfer between the scanner and tablet
Note
Ensure that the correct project is selected on the tablet before transferring data.
Note
Check that the windows at the infrared ports are free from dirt, dust and grease and are not excessively
scratched before commencing data transfer. Failure to do so may result in reduced data transfer range
or may prevent data transfer.
Data is transferred from the scanner to the tablet using the infrared connection. The infrared windows are
situated at the ends of scanner and the tablet.
Data can be transferred at any time when the scanner and tablet are switched on, the PS 200 S scanner is
displaying the main menu and infrared data transfer is activated on the tablet. On the tablet under "Project",
select the project into which the data is to be copied. Then select "Import" and "From PS 200 S" and confirm
by pressing the OK button. The infrared symbol then appears in the status area of the tablet.
Bring the scanner and tablet close together so that the infrared windows are facing each other. The scanner
and tablet recognize each other automatically and establish a connection.
42
English
Printed: 14.11.2016 | Doc-Nr: PUB / 5314765 / 000 / 00