YATO YT-73085 Manual Original página 9

Manómetor digital universal
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 38
DESCRIPTION
A multifunction meter is a digital measuring instrument designed to measure var-
ious electrical or physical quantities. The meter has a plastic casing, liquid crystal
display, and a range/measured quantity switch. The casing has measurement
jacks fi tted. The meter comes with test leads terminated with plugs. The meter
is sold without a battery.
Before using the meter, read the instruction manual in its entirety and keep
it for later use.
CAUTION! This meter is not a measuring instrument within the meaning of the
Metrological Act.
DESCRIPTION
The multifunction meter is a digital measuring instrument designed to measure
various electrical quantities.
Before using the meter, read the instruction manual in its entirety and keep
it for later use.
The meter has a plastic casing, liquid crystal display, and a measuring range
switch. The casing is fi tted with measuring jacks and a socket for transistor test-
ing. The meter is fi tted with test leads terminated with plugs and a socket for
testing transistors and small electronic components. The meter is sold without
a battery.
CAUTION! This meter is not a measuring instrument within the meaning of the
Metrological Act.
TECHNICAL DATA
Display: 3 5/6 digits LCD – greatest displayed result: 5999
Sampling frequency: 3 samples/sec
Overload marking: "OL" symbol displayed
Polarity marking: "–" sign displayed before the result
Battery: 6F22, 9 V
Fuse: F400 mA/600 V and F10 A/600 V
Working temperature range: 0 to 40
Storage temperature: –10 to +50
Outer dimensions: 188 × 86 × 44 mm
Weight (without batteries): 300 g
CAUTION! It is forbidden to measure electrical values exceeding the maxi-
mum measuring range of the meter.
Parameter
Catalogue no.
Range
600 mV
6 V
YT-73085
60 V
600 V
Notes
for 600 mV range: R
other ranges: R
Range
600 mV
6 V
60 V
600 V
Overload protection: 600 V
C at relative air humidity <75%
o
C at relative air humidity <85%
o
DC voltage
for 600 mV range: R
> 100 MΩ;
IN
other ranges: R
= 10 MΩ
IN
Resolution
0.1 mV
±(0.8% + 5)
1 mV
10 mV
0.1 V
Overload protection: 600 V RMS
AC voltage
> 100 MΩ;
IN
= 10 MΩ; f
= 40 ÷ 400 Hz
IN
IN
Resolution
Accuracy
0.1 mV
±(1.2% 8)
1 mV
10 mV
±(1% 8)
0.1 V
O R I G I N A L
GB
Direct current
for ranges 600 μA and 60 mA, U
for other ranges, U
Range
Resolution
600 μA
6000 μA
60 mA
600 mA
6 A
10 A
Overload protection: fuse 10A/ 600 V; range 10 A: current measurement >5A; measure-
Range
600 Ω
6 kΩ
60 kΩ
600 kΩ
6 MΩ
60 MΩ
Open circuit voltage approx. 0.25 V; Overload protection 400 mA/600 V RMS
Capacitance
Range
Resolution
60 nF
600 nF
6 nF
60 μF
600 μF
60 mF
Overload protection 400 mA/600 V RMS
Diode test
Measurement conditions
U
= 3 V; I
R
Overload protection 400 mA/600 V RMS
Range
–40
o
C to +1370
Accuracy
–40
F ÷ +2000
o
Overload protection 400 mA/600 V RMS Accuracy does not allow for thermocouple error.
The stated accuracy is valid for ambient temperature changes of not more than ± 1
±(0.8% 3)
If the ambient temperature changes ±5
Range
0.1% ÷ 99%
Input signal frequency range: 1 Hz – 5 kHz; Input voltage range: 4 V
Accuracy: ± % of the indication + weight of the least signifi cant digit
OPERATION
CAUTION! To avoid the risk of electric shock, disconnect the test leads and
switch off the meter before opening the casing.
Safety instructions
Do not operate the meter in an atmosphere with excessive humidity or in the
presence of toxic or fl ammable vapours, or in an explosive atmosphere. Before
each use, check the condition of the meter and the test leads. If you notice any
faults, do not start its operation. Replace damaged cables with new ones, de-
void of defects. In the case of any doubts, you should contact the manufacturer.
During measurement the test leads should be held by the insulated parts. Do
not touch the measurement points or unused measuring jacks of the meter. Dis-
connect the test leads before changing the measured quantity. Never carry out
I N S T R U C T I O N S
≤ 60 mV
AB
≤ 600 mV
AB
Accuracy
Range
0.1 μA
600 μA
1 μA
6000 μA
±(1% 7)
0.01 mA
60 mA
0.1 mA
600 mA
1 mA
6 A
±(1.5% 7)
10 mA
10 A
ment time <10 sec in intervals of >15 min.
Resistance
Resolution
0.1 Ω
1 Ω
10 Ω
0.1 kΩ
1 kΩ
10 kΩ
Accuracy
Range
0.01 nF
0.1 nF
1 nF
±(8% 5)
0 – 60 MHz
0.01 μF
0.1 μF
10 μF
Input voltage range: 0.5 V
load protection 400 mA/600 V RMS
Range
= 0.8 mA
hFE
F
Measurement conditions I
Temperature
Resolution
o
C
1
o
C
F
1
F
o
o
C, the specifi ed accuracy is achieved after 1 hour.
o
Duty cycle
Resolution
0.1%
Overload protection 400 mA/600 V RMS
Alternating current
f
= 40 ÷ 400 Hz
IN
Resolution
Accuracy
0.1 μA
1 μA
±(2.0% 15)
0.01 mA
0.1 mA
1 mA
±(2.5% + 10)
10 mA
Accuracy
±(1.2% 5)
±(1.5% 5)
Frequency
Accuracy
±(1.0% 5)
÷ 3 V
; Over-
PP
PP
Transistor test
hFE
0 ~1000
= 4 μA; U
= 2.2 V
B
CE
Accuracy
–40
C to 150
C: ±(3% 4)
o
o
150
C to 1370
C: ±(3% 3)
o
o
–40
F ÷ 302
F: ±(5% 4)
o
o
302
o
F ÷ 2000
o
F: ±(3% 3)
o
C.
Accuracy
±(2% 7)
÷ 10 V
pp
pp
9

Publicidad

Tabla de contenido
loading

Tabla de contenido