8.3
Technical data
Weight
g
Refrigerant
g
R134a (Kg)
SPL040
52
0.55
SPL050
58
0.82
SPL060
60
0.88
Calibration values
Expansion automatic valve
SPL040
SPL050--- 060
All manuals and user guides at all-guides.com
MIN.---MAX. Ambient temperature
Amb
During transport and
After
stockage
installation
0 ---50˚C
5 ---50˚C
Hot gas valve
7 AEV
9
HGV
2.2 bar
---
---
2.2 bar
Compressed
Air ---side
air inlet
max. working
g
temperature
t
t
pressure
230V±10%
Max
In
65˚C
16 bar
Fan pressure switch
High temperature safety thermostat
12 PV
13 HT
85˚C
ON: 10 bar
ON: 10 bar
OFF: 7 bar
130˚C
Compressed air
Compressed air
Minimum section
Minimum section
inlet/outlet
validated cable
F.L.A. [A]
F.L.A. [A]
for eletrical
for eletrical
connection
1ph/50Hz
2
Ø [mm
]
5.26
6.36
3 G 1.5
6.76
High pressure switch
15 HP
---
28 bar
Sound
pressure level
pressure level
BSP---F
[dB(A)]
1"1/2
55
Fan thermostat switch
16 TV
START: 46 (±3)˚C
DIFF: 9˚C
DIFF: 9˚C
STOP: 35 (±4)˚C
71
SPL040 ---060

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Starlette plus spl050Starlette plus spl060

Tabla de contenido