DRAIN PIPING WORK
Piping and drain hose installation
In case of right-side exit
• Cut out the knockout portion by the slits with a knife or pair of wire cutters as necessary.
In case of downward pipe exit
• Cut out the knockout portion by the slits with a knife or pair of wire cutters as necessary.
Slit (Body right)
Piping via left-hand connection
Bend the connecting pipe so that it is laid within 43 mm above the wall surface. If the connecting pipe is laid
exceeding 43 mm above the wall surface, the indoor unit could be unstable when set on the wall. When bending the
connecting pipes, always use a suitable bending tool to avoid damaging the pipes.
Bend the connection pipe within a radius of 30 mm.
To connect the pipe after installation of unit (figure)
Outward form of indoor unit
If the pipe is bent incorrectly, the indoor unit could be unstable on the wall.
After passing the connecting pipe through the pipe hole, connect the connecting pipe to the auxiliary pipes and
insulate as necessary.
All manuals and user guides at all-guides.com
Slit (Body right)
(To the front of the flare)
400 mm
Liquid side
300 mm
Gas side
R 30 mm
Use the handle of a screwdriver, etc.
NOTE
6