7.3

Sensing range setting

8020346.1DS6/2021-11-24 | SICK
Subject to change without notice
Minimum distance in mm (y) between the set sensing
range and background (white, 90%)
y
140
WTB16I-xxxxx1xx
2
1
120
18%/90%
6%/90%
100
80
3
90%/90%
60
40
20
0
0
400
800
1,200
1,600
(15.75)
(31.5)
(47.24)
(62.99)
Distance in mm (inch)
Figure 18: Characteristic line 4, WTB16 I-xxxxx1 xx, infra‐
red light
Minimum distance in mm (y) between the set sensing
range and background (white, 90%)
y
250
WTB16I-xxxxx4xx
(9.84)
200
(7.87)
18%/90%
2
150
1
(5.91)
3
6%/90%
90%/90%
100
(3.94)
50
(1.97)
0
0
500
1,000
1,500
2,000
(19.69)
(39.37)
(59.06)
(78.74)
Distance in mm (inch)
Figure 19: Characteristic line 5, WTB16 I-xxxxx4 xx, infra‐
red light
WTB16x-xxxxxx2xAxx with Teach-Turn adjustment:
The sensing range is adjusted by pressing the teach-in button (approx. 1-3 sec.).
Depending on the requirements, the potentiometer can be used for fine-tuning (without
pressing the teach-in button).
Clockwise rotation: Sensing range increased.
Counterclockwise rotation: Sensing range reduced.
The sensing range can also be adjusted using just the potentiometer. We recommend
placing the sensing range in the object, e.g.
range has been adjusted, the object is removed from the path of the beam, which
causes the background to be suppressed and the switching output to change
table
4).
1
white background (90%)
2
3
x
y
Example:
Sensing range on black, 6%,
x = 600 mm, y = 70 mm
A = Detection distance (depending on object remission)
x
1
white background (90%)
2
3
x
y
Example:
Sensing range on black, 6%,
x = 700 mm, y = 80 mm
A = Detection distance (depending on object remission)
x
see figure 20, page
O P E R A T I N G I N S T R U C T I O N S | WTB16
COMMISSIONING
50 /
700
100
25 /
1,000
100
10 /
1,500
100
0
100
500
1,000
1,500
(3.94)
(19.69)
(39.37)
(59.06)
Distance in mm (inch)
A
Adjustment range
BluePilot:
Sensing range
indicator (blue LED)
Teach-Turn
adjustment
50/
950
100
1,200
100
100
0
100
500
1,000
1,500
2,000
(3.94)
(19.69)
(39.37)
(59.06)
(78.74)
Distance in mm (inch)
Adjustment range
A
BluePilot:
Sensing range
indicator (blue LED)
Teach-Turn
adjustment
28. Once the sensing