Sirius SLT962 Instrucciones De Uso Y De Montaje página 15

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27
SLT963
FREE STANDING – FILTERING
VERSION INSTALLATION
Take the product out of the packaging and
place it on a suitable surface: we suggest to
use a soft material, such as a sponge or a
cloth.
Open the glass panel , rotating it as shown in
Fig. 10, and remove the grease filters.
Drill the holes on the ceiling , as shown in
Fig. 11, insert the plastic plugs into the ho-
les made, and then fix the ceiling brackets, as
shown in Fig. 12. The brackets, which being
telescopic can be adjusted in height , shall be
secured at their minimum extension.
Bring the hood close to the brackets previou-
sly fixed and connect the appliance to the
supply mains.
Secure the hood to the ceiling, by using the
screws supplied, as shown in Fig. 13.
BUILT IN – SUCKING VERSION
INSTALLATION
Take the product out of the packaging and
place it on a suitable surface: we suggest to
use a soft material, such as a sponge or a
cloth.
Open the glass panel , rotating it as shown in
Fig. 10, and remove the grease filters.
In the built-in installation, the stainless steel
external cover is not necessary.(Fig. 14).
A recess shall be created , where the appliance
will be placed, which shall have a 900 mm X
500 mm rectangular opening and depth ran-
ging from 160mm to 220 mm.
THE RECESS SHALL BE MADE AFTER IN-
STALLING THE APPLIANCE AND ESPECIALLY
AFTER CONNECTING THE AIR OUTLET PIPE
The recess shall be provided with a socket and
a round pipe of 150mm diameter, or a similar
section, for the air outlet
Drill the holes on the ceiling , as shown in
Fig. 11, insert the plastic plugs into the ho-
les made, and then fix the ceiling brackets as
shown in Fig. 12.
The ceiling brackets are telescopic , so their
height can be adjusted at 60 mm between the
ceiling and the hood.
You can choose one of the three air out- lets
shown in Fig. 15: fit the air outlet plastic flan-
ge in the desired outlet; the remaining outlets
shall be closed with the specific metal caps , as
shown in fig. 15.
Bring the hood close to the brackets previou-
sly fixed and then connect the appliance to the
supply mains.
Secure the hood to the ceiling, by using the
screws supplied, as shown in Fig. 13.
EXTERNAL MOTOR VERSION
Connect the external motor cable to the
terminal board found inside the plastic box
of the appliance wiring . Make sure to re-
spect the colors of cables when performing
the electrical connection (fig.16).
15
SLT963

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Slt963

Tabla de contenido