2 Description
2.1 Use of the product as directed
The tool is designed for measuring distances and direc-
tions, calculating target positions in 3 dimensions and
the values derived from these positions and for laying
out points using given coordinates or values relative to a
control line.
To avoid the risk of injury, use only genuine Hilti ac-
cessories and insert tools.
Observe the information printed in the operating instruc-
tions concerning operation, care and maintenance.
Take the influences of the surrounding area into account.
Do not use the appliance where there is a risk of fire or
explosion.
Modification of the tool is not permissible.
3 Technical data
Right of technical changes reserved.
NOTE
The only difference between the POS 150 and POS 180 is the angle measurement accuracy.
Telescope (POS 150/180)
Telescope magnification
Shortest target distance
Telescope angle of view
Lens aperture
Minimum focusing distance
Compensator (POS 150/180)
Type
Range, fine
Range, coarse
Accuracy
Sensitivity of circular bubble level in tribrach
Angle measurement
POS 150 accuracy (DIN 18723)
POS 180 accuracy (DIN 18723)
Laser distance measurement / laser pointer (POS 150/180)
Wavelength
Laser class
Beam divergence
Maximum output power
2.2 Description of the tool
The POS 150/180 total station can be used to define ob-
jects as dynamic positions within a given space or area.
The tool is equipped with horizontal and vertical circles
with digital graduation, two electronic levels (compensat-
ors), a coaxial electronic distance meter (EDM) incorpor-
ated in the telescope and an electronic processor system
for calculating and saving data.
The built-in target acquisition system allows prisms to be
targeted automatically and their positions tracked even
when they move. The prism's position is determined con-
tinuously and processed in the application on an ongoing
basis. The total station is operated using controller POC
100.
Hilti PROFIS Layout, a PC application provided by Hilti,
can be used to transfer data in both directions between
the total station and a PC, for data processing and
for exporting data to other systems. Data can also be
transferred directly from the controller to a USB data
storage device.
31 ×
1.5 m (4.9 ft)
1° 30'
50 mm (2")
1.5 m (5 ft)
Dual-axis, liquid
±5.5'
±3°
0.5"
±8' / 2 mm
5"
3"
660 nm
3R
0.27 mrad
< 5 mW
en
39