Lincoln Electric Square Wave TIG200 Manual Del Operador página 8

Ocultar thumbs Ver también para Square Wave TIG200:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

SQUARE WAVE® TIG 200
TECHNICAL SPECIFICATIONS
SQUARE WAVE TIG 200 (K5126-1)
WELDING
INPUT POWER:
MODE
120 V
TIG
1 PHASE
(AC/DC)
60 Hz
220 / 230 V
STICK
1 PHASE
(DC)
50/60 Hz
TIG RATED OUTPUT:
(1)
CURRENT/DUTY CYCLE
125 A / 25 %*
INPUT
100 A / 40 %
VOLTAGE
120 V
85 A / 60 %
200 A / 25 %
160 A / 40 %
230 V
130 A / 60 %
* 110 A for AC TIG
(1) Based upon 10 minute time period (i.e., for 60% duty cycle, it is 6 minutes on and 4 minutes off)
(2) Also called 'inverse time' or 'thermal/magnetic' circuit breakers; circuit breakers that have a delay in tripping action that decreases as the
magnitude of current increases.
(3) To prevent nuisance breaker trips, refrain from operating at maximum output and exceeding rated duty cycle.
LENGTH
19.22 IN. (488 MM)
10.75 IN. (282 MM).
OPERATING TEMPERATURE RANGE
STORAGE TEMPERATURE RANGE
All manuals and user guides at all-guides.com
OUTPUT RANGE
OPEN CIRCUIT VOLTAGE
INPUT
OUTPUT
RANGE
RANGE
120 V
10-125 A
230 V
10-200 A
120 V
10-90 A
230 V
10-170 A
STICK RATED OUTPUT:
CURRENT/DUTY CYCLE
75 A / 20 %
INPUT
VOLTAGE
120 V
65 A / 60 %
170 A / 20 %
230 V
100 A / 60 %
PHYSICAL DIMENSIONS
WIDTH
HEIGHT
14 IN. (358 MM)
TEMPERATURE RANGE
14°F~104°F (-10°C ~ +40°C)
14°F~104°F (-10°C ~ +40°C)
(OCV)
AVERAGE OCV - 62 V
PEAK OCV - 140 V
VRD OCV
- 13.5 V
PEAK
RECOMMENDED BREAKER AND FUSE SIZES AND
(1)
MAXIMUM EFFECTIVE CURRENT
INPUT
FUSE (SUPER LAG)
VOLTAGE
OR BREAKER SIZE
230 V
30 A
120 V
20 A
WEIGHT
46 LBS (21KGS)
A-1
INSTALLATION
EFFECTIVE
MAXIMUM
(2)(3)
CURRENT DRAW
CURRENT DRAW
14.7 A
25 A
15 A
21.5 A
OTHER PARAMETERS
PROTECTION CLASS
IP21S