5. Disconnect the two cables for power supply to the lamp by disconnecting the plugs at the
contacts.
6. Loosen the two screws of the upper bracket approximately one turn and push the spring-load-
ed lower bracket downwards.
7. The lamp may now be tilted upwards and pulled downwards out of the retaining frame.
5
8. Place the new lamp in the retaining frame in the same orientation. When doing so, ensure that
the spring-loaded lower bracket is back in the holding position and re-tighten the two screws
of the upper bracket.
9. Plug the cables for the power supply into the contacts (reversal of polarity not possible).
10. Remove the old seal from the groove in the lamp compartment surround.
11. Thoroughly clean the groove and the contact surface of the fan unit. Make sure that the con-
tact surfaces of the seal are free from foreign objects and dirt.
12. Remove the new seal from the packaging and remove any residues of the mould release
agent.
13. Now place the seal positively into the groove. Ensure that the seal is not twisted.