14. Place the fan unit flat on the lamp compartment.
15. The screws of the fan unit must now first be tightened crosswise with low force.
16. The screws of the fan unit must then also be tightened crosswise to 6 (± 0.5) kgf-cm.
17. After mounting the fan unit, perform a leak test.
18. After the leak test, fasten the safety cable of the rear head cover in the appropriate position,
place the head cover on the spotlight head and screw it in place using the previously loosened
screws (10 (± 0.5) kgf-cm).
Never operate the spotlight without the fan unit and head cover!

CALIBRATING THE LAMP

WARNING:
Calibration of the lamp may be carried out by qualified personnel only. If you are not
qualified to do this, do not attempt to calibrate a lamp yourself. Consult a qualified
professional instead.
A hot discharge lamp is under high pressure and can therefore spontaneously
explode. Let the spotlight cool for at least 30 minutes before opening it!
When calibrating the lamp, wear protective glasses and protective gloves!
When carrying out any work, make sure that no foreign bodies enter the housing!
In order to maintain the seal of the OTOS H5 moving head according to protection
class IP65, a new seal must be inserted at the corresponding location after calibrating
the lamp. Carefully follow each step in the instructions below.