NOTE: the microfibre filter (P) must not be used with water
filtering function.
• Sponge filter (Q): (Fig. 60) to be used for liquid suction.
Wash from inside to outside with running water. Best to
replace every 6 months.
• HEPA air filter (X): (Fig. 61) Periodically inspect by lifting
the hooking lever. Best to replace every 6 months.
• Carbon filter (Y): (Fig. 62) has very high filtering capacity. It
traps the motor carbon dust generated during operation.
Inspect monthly by removing the retaining grille; replace if
dirty. Best to replace every year.
CAUTION! Handle with care, do not inhale and keep out of
reach of children.
CAUTION! Repairs should be carried out only by an authorised Service Centre.
Breakdowns may occur when the appliance is not used properly. The following table describes a
few problems and explains how to solve them. If our solutions do not help, call an Authorised
Service Centre.
TROUBLE
- After switching on, the no-
water pilot light (L) flashes and
the appliance is beeping
- The appliance is ready for use
but there is no suction and
steam
- The steam-ready pilot light is
on but no steam is coming out
- When working, an attachment
falls off
- When working, the suction
power drops
52
15 TROUBLESHOOTING
CAUSE
- Low water level in the tank (L) - Fill the distilled water tank
- The quick connector of the flex
tube is not fitted properly
- The steam safety lock (32) is on - Release the safety lock
- The steam adjustment knob (J)
is in the closed position
- The attachment has not been
connected properly
- The attachment is clogged
Fig. 61
X
Fig. 62
SOLUTION
- Make sure that the quick
connector (27) is hooked
properly into the socket
- Turn the steam adjustment
knob (J) to open position
- Connect the attachment
properly
- Check and clean the attachment
Y
EN