Diamond ATLANTIS TM69 LED Manual De Usuario página 42

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

TROUBLESHOOTING SYSTEM PROBLEMS
PROBLEM
WATER SOFTENER
IS NOT DRAINING WATER
EXCESSIVE WATER
INSIDE THE TANK
OR OVERFLOW
RESIN IS COMING OUT
OF THE WATER SOFTENER
RESIN IS COMING
OUT OF THE DRAINAGE
THE WATER SOFTENER DOES
NOT STOP REGENERATING
WATER PERMANENTLY
COMES OUT OF THE DRAINAGE
ALL THE FIGURES ON THE
PANEL ARE LIT UP
THE DISPLAY
DOES NOT WORK
ONLY E1 APPEARS
FLASHING ON THE SCREEN
POSITION
Very low pressure when
entering the equipment.
Blocked drainage pipette.
Dripping in the drainage pipette. Check the pipette.
Broken or damaged injector.
Washing time is excessive.
Obstructed injectors or drainage. Review injectors or drainage gum.
Drainage tube joined by a "Y"
with the outlet pipe.
Obstructed Aircheck.
Suction tube or Aircheck pipe
bend in bad shape.
Perforated container.
Air has got into the system.
Broken strainers.
Air has got into the system.
Broken strainers.
Controller error.
The valve body is badly adjusted
or there are impurities in the discs
Power cut during the
regeneration.
The connection between the
panel and the board is damaged.
The panel is damaged.
The transformer is wet or
damaged.
The connection between the
panel and the board is damaged.
The board is damaged.
The panel is damaged.
Electricity doesn't reach the panel. Check the electricity supply and the cables.
The connection between the panel
and the board is in poor condition.
The mechanical motor has
malfunctioned
The control board has
malfunctioned.
The cable between the motor and
the board has malfunctioned.
The motor is in poor condition.
Increase the entry pressure.
Dismantle the pipette and review the "gum".
Change the injector.
Adjust the programming time.
Lower the drainage.
Clean or replace the Aircheck.
Change it for a new one.
Change the container.
Check the installation to see that it does not happen.
Change strainers.
Check the installation to see that it does not happen.
Change strainers.
Change the controller.
Change it or, if it is shaped, undo it and check it.
Put the disc into service manually.
Change the connection cable.
Change the panel.
Check or change the transformer.
Change the connection cable.
Change the board.
Change the panel.
Change the connector.
Check the motor.
Change the control board.
Change or check the cable.
Change the motor.
16
SOLUTION
EN

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Atlantis tm69 lcd

Tabla de contenido