G
UP INSTALLATION with articulated arm for outward openings
B
Positioning of drills to fasten UP automation with articulated arm (AA12050)
Pic. A
20 mm from door hinge
electric cable entry
X* = 20mm (STANDARD)
~ 6 mm
1 - Check that the wall is straight and
smooth
2 - Drill the holes respecting the measures
as in Pic.A.
3 - Insert the dowels (stand. equipment) or
threaded M8 screws
4 - Insert the screws but leave them loosen
(~6 mm) in order to hook up and shift
(rightward) the automation
5 - Fasten firmly the automation to the wall
tightening the M8 screws
= Drill a hole Ø6,5 and thread it in order to use M8 screws - Drill a hole Ø14 if you prefer to use Fischer dowels.
X* = STANDARD + ACG9485 (75 mm)
2
42
30 mm from door hinge
electric cable entry
1