LIMIT SWITCHES ADJUSTMENT (to perform only without power supply)
Stop and exclusion safety in opening limit switches adjustment
Cam that activates the limit switch that excludes the safety sensor in opening
2
1
Pic. A
"B" limit switch for maximum opening stop
"A" limit switch that excludes the safety sensor in opening
Cam that activates the limit switch for maximum opening stop
NC terminal FCA11
NO terminal PHOTO RAL 12
WARNING:
In order to adjust the cams, loosen the screws 1 and 2 (pic.A).
The cams adjustment must be done operating manually the leaf, before
doing the set-up.
Once the adjustments are over, tighten the screws.
45
B
A
COM terminal COM10 or 31
G
B