Data Transfer - Hilti PS 250 Manual De Instrucciones

Ocultar thumbs Ver también para PS 250:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

The green LED lights constantly: The adapter is
switched on and is ready for operation.
The red LED blinks rapidly: Battery charge state is
low.
The green LED blinks: The adapter has just been
switched on.
en
The green LED blinks: Data transfer in progress.
The red LED blinks and the adapter switches itself
off: Memory is 95% full.

7.4 Data transfer

7.4.1 Transferring data from the scanner to the
monitor 2
NOTE
Ensure that the correct project is selected on the monitor
before transferring data.
NOTE
Check that the windows over the infrared ports are
free from dirt, dust and grease and are not excessively
scratched before commencing data transfer. Failure to
do so may result in reduced data transfer range or may
prevent data transfer.
Data is transferred from the scanner to the monitor us-
ing the infrared connection. The infrared windows are
situated at the ends of scanner and the monitor.
Data can be transferred at any time when the scanner
and monitor are switched on, the PS 200 S scanner is
displaying the main menu and data transfer by infrared is
activated on the monitor.
The project into which the data is to be copied is selected
on the monitor under Projects.
Then select Import and confirm "From PS 200 S" by
pressing the OK button. The infrared symbol then appears
in the status area of the PSA 100 monitor.
Bring the scanner and monitor close together so that
the infrared windows are facing each other. The two
devices recognize each other automatically and establish
communication.
This screen appears on the scanner and a beep sounds:
Press the Confirm button on the scanner to begin import-
ing all scan data into the selected project.
This screen appears on the scanner while data transfer
is in progress and the red LED on the scanner blinks
continuously.
26
Data transfer takes between 1 and 15 seconds, depend-
ing on the number and length of scans contained in the
scanner.
This screen is displayed by the scanner when data trans-
fer is complete:
Press the Confirm button on the scanner again to end the
data transfer procedure.
The scan data in the scanner is then deleted automati-
cally.
7.4.2 Transferring data from the scanner to the
adapter 3
DANGER
Use the adapter only indoors. Avoid moisture ingress.
CAUTION
Check that the windows over the infrared ports are
free from dirt, dust and grease and are not excessively
scratched before commencing data transfer.
Failure to do so may result in reduced data transfer range
or may prevent data transfer.
Data is transferred from the scanner to the adapter us-
ing the infrared connection. The infrared windows are
situated at the ends of scanner and the adapter.
NOTE
The maximum range of the infrared connection is approx-
imately 30 cm (11.8"). The maximum permissible angle
between the scanner and monitor for successful data
transmission at close ranges (up to 10 cm (4")) is ± 50°
relative to the axis of the infrared port on the adapter.
At a distance of 15 cm (6") this angle is reduced to ±
30°. At a distance of 30 cm (11.8") the scanner must be
accurately aligned with the monitor to ensure successful
data transmission.
Bring the scanner and adapter close together so that
the infrared windows are facing each other. The two
devices recognize each other automatically and establish
communication. The following screen appears on the
scanner and a beep sounds: