The value indicates the typical accuracy of the depth measurement (deviation
from actual) in mm or, respectively, in inches.
4.3.1 Imagescan and Blockscan: Rebar diameter is known
Please refer to the bar diameter tables in the annex (1.).
4.3.2 Imagescan and Blockscan: Rebar diameter is not known
Please refer to the bar diameter tables in the annex (2.).
4.3.3 Quickscan recording: Rebar diameter is known
Please refer to the bar diameter tables in the annex (3.).
4.3.4 Quickscan detection with depth measurement: Rebar diameter is known
Please refer to the bar diameter tables in the annex (4.).
4.3.5 Quickscan detection
Depth measurement is accurate to within ±10% of the effective depth.
4.3.6 Accuracy of bar diameter measurement
± 1 standard diameter when rebar spacing : depth of cover ≥ 2 : 1. Bar diameter measurement is possible only at
depths of up to 60 mm (2.4").
4.3.7 Reinforcing bar location accuracy
Bar center locating accuracy (all modes): Typically ± 3 mm (0.12") relative to the measured position, when the ratio of
bar spacing : depth of cover is ≥ 1.5:1.
4.4 Technical data for PS 200 S scanner
Maximum scanning speed
Memory type
Memory capacity
Screen type / size
Screen resolution
Dimensions
Weight (with PSA 80 battery pack)
Minimum battery life (with PSA 80 battery pack)
Automatic power-off
Backup battery type / life
Scanner-monitor data interface
Scanner-monitor data transfer time
Infrared range
Infrared output power
4.5 Technical data for PSA 55 infrared adapter
Battery
Dimensions
Weight
0.5 m/sec (1.64 ft/s)
Built-in flash memory for data
9 Imagescans plus up to 30 m (98 ft) of recorded
Quickscan (max. 10 scans)
LCD / 50 × 37 mm (2" x 1.5")
128 × 64 pixels
260 × 132 × 132 mm (10.2 x 5.2 x 5.2")
1.4 kg (3.09 lb)
8 hours under typical conditions
5 min. after last press of a button
Lithium / 10 years (typically)
Infrared
≦16 s for 9 images, ≦2 s for 1 image
Typically 0.3 m (1 ft)
Max. 500 mW
1 x 1.5 V AAA
90 x 50 x 28 mm (3.5 x 2 x 1.1")
65 g (0.14 lb)
en
9