Installer Checklist - Thermador Professional Pro Grand Serie Manual De Instalación

Ocultar thumbs Ver también para Professional Pro Grand Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

1. Place each burner cap on its correct burner base per
its corresponding letter designation.
2. Place burner cap gently on top of base so that the
prongs of the burner base fit snugly into the groove of
the burner cap.
Checking the burner cap placement
Check each burner to make sure there is no gap
between the burner cap and burner base.
You may gently try to move the burner caps from side
to side to check if the caps are properly placed on the
burner bases.
When properly placed, each burner cap will rest flat
on top of its burner base, and completely cover the
star-shape of the burner base when viewed from the
top as shown below.
To install the burner grates
1. Place grates flat-side down and align into the
rangetop recess.
2. Grates should rest flush against each other and
against the sides of the recess.
To test burner ignition
See figures below for appropriate flame characteristics. If
any of the rangetop burners continue to burn mostly or
completely yellow, verify that the burner cap is positioned
properly on the burner base, then re-test. If flame
characteristics do not improve, call Thermador service.
1. Select a rangetop burner knob. Push in and turn the
knob to HI.
The igniter will produce a clicking sound. Once
the air has been purged from the supply lines, the
burner should light within four seconds.
21
2. Turn burner to LO. Verify that the flame completely
surrounds the burner.
There should be a flame at each burner port and
there should be no air gap between the flame and
the burner. If any burners do not carry over, call
Thermador service.
3. Repeat the ignition and flame test for each rangetop
burner.
If the flame is completely or
mostly yellow, verify that the
regulator is set for the correct
fuel. After adjustment, retest.
Some orange-colored streaking
is normal during the initial start-
up. Normal for LP gas.
Soft blue flames are normal for
natural gas
4. Allow unit to operate 4-5 minutes and re-evaluate
before making adjustments.
The burners that feature XLO
on and off when the knob is set to the XLO function. This
is normal operation.
When flame is properly adjusted:
There should be a flame at each burner port.
There should be no air gap between the flame
and burner port.
Call Thermador service if:
Any of the burners do not light.
Any of the burners continue to burn yellow.

Installer checklist

Final check
Specified clearances maintained to cabinet surfaces.
Unit level – front to back – side to side.
Burner caps positioned properly on burner bases.
All packaging material removed.
Kick panel in place and screws secure.
Verify flame at each burner. Flame may need to burn
for several minutes to remove impurities from the
gas lines.
Verify that the ExtraLow
around the entire burner.
INSTALLER: Leave the Home Connect™ instruction
leaflet with the owner of the appliance. In order to
utilize the full feature potential of the appliance, the
owner should download the Home Connect™ app
on their smart device and pair the appliance to the
home's Wi-Fi device. (Does not apply to 30'' Range
models.)
®
, cause the flame to cycle
®