Setting The Time - Bosch Junkers TFQ 2 W Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 19
GB
-Knob (h)
in Position
Left stop
Middle position
Right stop
Note: * A prerequisite is a correctly adjusted heating curve on the TA... regulator so that with-
out room temperature sensing, approximately 20 °C room temperature will be achieved.
5.4
Timer
With the selection of the appropriate opera-
ting mode, the timer makes possible the au-
tomatic switching between normal and redu-
ced modes. The shortest switching interval
(closest distance between two riders on the
7-day ring ) is two hours. The positioning ac-
curacy (distance between two adjacent posi-
tions on the 7-day ring) is 30 min.

5.4.1 Setting the Time

Turn the Plexiglas disk with the printed minu-
te hand (i) to set the actual time of day. Turn
the disk only in the clockwise direction. The
7-day ring (j) must not be turned. Observe
that the clock runs in 7-day operation. The
time setting (24 hr and weekday) can be
read off of the 7-day ring (j) at the time mar-
ker (m).
5.4.2 Setting the Switching Times
To set the switching times, remove the cover
(e) of the timer ( ).
12
Reduced mode
Feed Temperature Change
–50 K
–25 K
±0 K
1
Switch (p) in Position
Operational Mode Switch (f) in Position
Economy mode
–25 K
–25 K
–25 K
• Red rider
• Blue rider
For correct operation of the timer, the riders
must be positioned alternately in red/blue se-
quence.
Stick the red and blue riders (l) for each day
at the desired position of the 7-day ring (j).
Riders that are not used remain in the stora-
ge position (k).
5.4.3 Operating Reserve
After at least three days of operation from
the commercial power source, the timer has
an operational reserve available of approx.
50 hours. During this period, the timer conti-
nues to run on a rechargeable battery.
Take care that the power supply is not inter-
rupted for longer than 50 hours (also when
the heater is switched off). Deep discharging
shortens the service life of the rechargeable
battery!
Reduced mode
Economy mode
Approx. Room Temperature *
12 °C
14,5 °C
17 °C
= Normal mode.
= Reduced mode.
TFQ 2 W
17 °C
17 °C
17 °C

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

7 744 901 064

Tabla de contenido