Terminals

TIMER OUT Terminal

The VCR outputs +12 V from the TIMER OUT
terminal according to the timer setting on the TIMER
SET display. The terminal outputs the signal even if
the timer recording mode is off.
TIMER OUT terminal
COM terminal
TIMER OUT terminal
Timer starts.

WARNING OUT Terminal

This terminal will help you to know when something
wrong has happened to the VCR during recording.
The VCR outputs a signal from WARNING OUT
terminal.
WARNING OUT terminal
COM terminal
To reset, press STOP p or EJECT 6,
Tape recording stops.
if the clog detection function works and
the VCR gives warning, otherwise,
press ALL RESET.
Note
To turn the clog detection function off, set CLOG
DETECT to N (no) on the SET UP 3 display.
When the VCR detects the tape end or the time counter
shows "5H57M" or "7H57M" (depending on the
setting of the TAPE switch) during recording, the
output level becomes 0 V DC. To resume the 5 V
output, press the operation button (EJECT 6, REC r,
FF ), REW 0 or PLAY z, etc.).
12 V
REC mode
0 V
Recording
Timer stops.
mode
Output
signal
REPEAT REC mode
Recording
mode
Output
signal
Set TAPE END OUT to –3M or END on the SET UP 3
display.
• –3M: the time counter shows "5H57" (three minutes
before the tape end when using T-120 tape) or
"7H57M" (three minutes before the tape end when
using T-160 tape) and a signal is output from the
TAPE END OUT terminal (recording will be
5 V
continued to the end of the tape).
0 V
• END: the VCR detects the tape end.

TAPE END OUT Terminal

COM terminal
TAPE END OUT terminal
Tape end
Beginning of tape
Rewind
Tape end
Rewind
2 sec.
Press operation
button
Stop
5 V
0 V
Beginning of tape
Recording
5 V
0 V
35