10 Troubleshooting

This section describes issue characteristics and the
corrective actions.
Problem
The AC fan does not run after the power
is turned on.
The LED on the device does not turn
green when the AC is on.
The LED on the device indicates a fault
and fast-flashes red (three flashes/
second).
The LED on the device indicates a fault
and flashes slowly (one flash/second).
An ammeter/multimeter test reading
indicates an inrush current that is too low
or too high.
The AC compressor runs correctly,
but an inrush current reading does not
detect a reduction in the current.
A meter equipped with an inrush current
measurement indicates the inrush
current that is too low or too high.

11 Disposal

Place the packaging material in the appropriate
M
recycling waste bins, whenever possible. Consult
a local recycling center or specialist dealer for
details about how to dispose of the product in
accordance with all applicable national and local
regulations.
EN
Possible Cause
The connections are installed
incorrectly.
The connections are loose.
No voltage is detected between the
supply side and the device.
A low voltage is detected between
the supply side and the device.
If the AC is running on a power
inverter, the AC has exceeded the
inverter's power rating.
The compressor has overheated.
The compressor is faulty.
The air flow over the condenser is
insufficient.
The ammeter or multimeter used does
not have the adequate time resolution
to capture a proper reading.
The connections are loose.
The LED on the device indicates a fault
and flashes red.

Limited 1-Year Warranty

LIMITED 1-YEAR WARRANTY AVAILABLE AT
DOMETIC.COM/EN-US/TERMS-AND-CONDITIONS-
CONSUMER/WARRANTY.
IF YOU HAVE QUESTIONS, OR TO OBTAIN A COPY
OF THE LIMITED WARRANTY FREE OF CHARGE,
CONTACT:
DOMETIC CORPORATION
CUSTOMER SUPPORT CENTER
5155 VERDANT DRIVE
ELKHART, INDIANA 46516
1-800-544-4881
Recommended Solution
Verify the connections are installed correctly.
Verify the connections are tight and secure.
• Verify the connections are installed correctly.
• Verify the circuit breaker is functioning
properly and reset if it is tripped.
• Verify the thermostat is functioning properly;
contact the Customer Support Center.
• Contact the Customer Support Center.
Check the power rating of the power inverter.
Verify the compressor connections are installed
correctly.
Contact the Customer Support Center.
Clean the condenser coil with an appropriate
coil cleaning product.
Use a meter equipped with an inrush current
measurement.
Verify the connections are tight and secure.
Contact the Customer Support Center.
Troubleshooting
29