Installation guide
Problems
The roller shutter is not
operational.
The roller shutter stops too
soon.
The roller shutter does not
stop when it reaches the
lower end limit position.
The roller shutter does not
stop when it reaches the
upper end limit position.
-
Copyright © 2008 - 2017 Somfy Activités Société Anonyme. All rights reserved.
Possible causes
The wiring is incorrect.
The motor is hot.
The control point is not
compatible.
The module used is not
compatible.
The roller shutter is encoun-
tering friction when it moves:
friction of the runners, the
unit, etc.
The motor has been instal-
led in a new roller shutter.
The mountings used are not
correct.
The roller shutter locking
system in the upper position
is not correct.
ilmo 50 S WT
Solutions
Check the wiring and modify
it if necessary.
Wait until the motor cools
down.
Check for compatibility and
replace the control point if
necessary.
Check that the module used
is the ilmo2 WT module.
Check the roller shutter
installation and correct any
friction.
If the problem continues,
restore the motor to its
original configuration.
Restore the motor to its
original configuration,
see the section entitled
"Restoring the original
configuration".
Check that the roller shutter
is mounted to the roller tube
using rigid links or bolts.
Check that the roller shutter
is fitted with end stops
screwed onto the last slat,
fixed or removable stops
incorporated in the runners
or an end slat acting as an
end stop.