Stove Phase General Layout; Description Of Alarms - Ravelli R 1000 Pro Manual De Uso Y Mantenimiento

Ocultar thumbs Ver también para R 1000 Pro:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 225
EN
Rev.1 29/07/2021
Pag.46

Stove phase general layout

Phase
FINAL CLEANING
IGNITION
WAITING FLAME
FLAME LIGHT
WORK
FIRE POT CLEANING
MODULATION
ECO STOP
T ON / T OFF
WAITING START
WAITING RESTART
HOT SMOKES
OFF
ANOMALY (general)

Description of alarms

AL
Warning
AL 01 BLACK - OUT
AL 02 SMOKE SENSOR
AL 03 HOT SMOKE
AL 04 FAN BROKEN
Use and maintenance manual R 1000 Pro
Description
The stove is switching off, the cooling phase is not yet completed
The ignition phase has started,the pellets are loaded into firebox
The pellet is lighted by the hot air passing through the ignition candle
The flame is visible in the fire pot
The stove completed switch ON phase; you can change power
The stove is performing the cleaning
The room temperature set has been reached
Comfort Clima activated, temperature set has been reached; the stove is off.
The room sensor is off or an external thermostat has been connected and the room set
is set to EXT
The stove is cooling DOWN: when stove is cooled down can start automatically
The stove is in the cooling DOWN: when stove is cooled down can restart automatical-
ly.
The maximum fume temperature threshold has been reached. To facilitate cooling, the
stove brings the capacity to a minimum with ventilation at max power level
The stove is off
The stove has detected an anomaly; refer to the troubleshooting chapter.
Reason
No electricity supply during working phase
The smoke sensor is malfunctioning
The smoke sensor has been disconnected from
the board
Combustion in the fire pot is not optimal
The centrifugal fan is defective
Smoke extractor encoder is not functioning or not
correctly connected
No electricity supply to smoke extractor
The smoke extractor is blocked
Solution
Press the off button and repeat switching on the
stove
If the problem continues, contact the area Techni-
cal Assistance Centre.
Please contact the local Technical Assistance
Centre
Please contact the local Technical Assistance
Centre
Switch off the stove, clean the fire pot and regu-
late combustion with the setting of the pellets.
Contact local Technical Assistance Centre.
If the problem continues, contact the area Techni-
cal Assistance Centre.
Contact local Technical Assistance Centre.
Contact local Technical Assistance Centre.
Contact local Technical Assistance Centre.

Publicidad

Tabla de contenido
loading

Tabla de contenido