92001i-EU 1900W RATED PORTAbLE INvERTER GENERATOR
Cleaning the Generator
CAUTION
DO NOT spray generator directly with water.
Water can enter the generator through the cooling slots and
damage the generator windings. It can also contaminate the
fuel system.
1. Use a damp cloth to clean exterior surfaces of the
generator.
2. Use a soft bristle brush to remove dirt and oil.
3. Use an air compressor (25 PSI) to clear dirt and debris
from the generator.
4. Inspect all air vents and cooling slots to ensure that they
are clean and unobstructed.
To prevent accidental starting, remove and ground the spark
plug wire before performing any service.
Changing the Engine Oil
Change oil when the engine is warm. Refer to the oil
specification to select the proper grade for your operating
environment.
1. Set the generator on top of a work bench or table.
2. Loosen the cover screws and remove the maintenance
cover.
3. Remove oil fill cap/dipstick.
4. Tilt the generator on its side and allow the oil to drain
completely.
5. Add oil according to Add Engine Oil in Assembly section.
DO NOT OVERFILL. Oil not included for routine
maintenance.
6. Reinstall the maintenance cover.
7. Dispose of used oil at an approved waste management
facility.
Once oil has been added, a visual check should show oil
about 1-2 threads from running out of the fill hole. If using
the dipstick to check oil level, DO NOT screw in the dipstick
while checking.
Cleaning and Adjusting the Spark Plug
1. Remove the maintenance cover.
2. Remove spark plug access cap from the top panel.
3. Remove the spark plug cable from the spark plug.
4. Use a spark plug socket tool (not included), or a
13/16 in. (21 mm) socket (not included )but can be bought
separately to remove the plug.
5. Inspect the electrode on the plug. It must be clean and not
worn to produce the spark required for ignition.
6. Make certain the spark plug gap is
0.024 - 0.031 in. (0.6 - 0.8 mm).
19
OPERATION
NOTICE
SPARK PLUG GAP
EN