8. RS-232 OUTPUT

The BW Series of scales can be ordered with an optional RS-232 output.
Specifications:
RS-232 output of weighing data
ASCII code
4800 Baud
8 data bits
No parity
Connector:
Type 9 pin d-subminiature socket
Pin 2
Pin 3
Pin 5
Data Format for normal weighing operations, parts counting or recalling of totals from memory will all be different.
Normal Output
GS 1.234
No.. 1
Total 1.234 Kg
<lf>
<lf>
When percent weighing, the output is the weight will be show in percent only
GS 100.00%
<lf>
<lf>

9. SETTINGS

The scale has 6 parameters that can be set by the user. These allow the user to set the scale for:
• Show the weight in increases of weight to minimise the damage that can cause vibrations, wind or other environmental conditions.
• Control the backlight of the screen. It can't be necessary turn off this light for maximize the duration of the battery.
• Select the automatic accumulation, manual or install the RS-232 interface to print the weight continuously.
• Program when it has to make accumulation and when it has to print.
• Program the value of auto zero.
• Select another unit of weight in addition to the standardProgrammer la valeur d'auto zéro.
For acces to the parameters you must press the buttons
If"M" is verified, press on the countdown
The screen will show "XX Inc". The first value that show is the value of error of increase of the Scales. To select an increase of different
value, press the button
For example, with a weight of 15kg on the scales the standard increase is of 0.5, the value can be changed of 1,0g to 2,0g.
Input
Output
Signal Ground
GS for Gross weight, NT for net weight and a unit of
This number increments every time a new value is stored in memory
The total value stored in memory
Includes 2 line feeds .
GS for Gross weight, NT for net weight and a unit of weight.