Component Disassembly For Descaling/Sanitizing - Manitowoc CNF201 Manual De Instalación, Operación Y Mantenimiento

Ocultar thumbs Ver también para CNF201:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Section 4

Component Disassembly for Descaling/Sanitizing

The ice machine must be disassembled descaled and
sanitized every six months.
Do not mix Descaler and Sanitizer solutions together. It
is a violation of Federal law to use these solutions in a
manner inconsistent with their labeling.
1. Turn off water supply to ice machine.
Wear rubber gloves and safety goggles (and/or face
shield) when handling Ice Machine Descaler or Sanitizer.
2. Place toggle switch in the CLEAN position for 30 seconds
to drain water from reservoir, then move toggle switch
to OFF position.
3. Run dispenser to transfer all ice from the bin to a
container.
Disconnect electric power to the ice machine at the
electric switch box before proceeding.
4. Disconnect electrical power to the ice machine.
5. Remove top cover.
A. Remove two thumbscrews.
B. Lift up on top cover to remove.
Remove
Screws
Part Number: 000015202 Rev 01 07/22
Caution
Warning
Warning
6. Remove front cover.
A. Lift up on front cover.
B. Pull forward to disengage keyhole slots.
7. Remove ice chute cover.
A. Turn the two thumbscrews 1/4 turn.
B. Lift to remove cover.
Maintenance
Loosen
Thumbscrews
19

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Cnf202

Tabla de contenido