Error
OVER-VOLTAGE FAULT
001
Check the electrical installation
UNDER-VOLTAGE FAULT
002
Check the electrical installation
005
Earth current fault
POWER SOURCE
010
Thermal protection
Fan
011
Fan default.
TRIGGER
012
A trigger is being pressed
MOTOR
015
Unable to reach the required speed
Overload, please check your settings
019
Press and release the trigger to erase
Problem with welding start-up
020
Please check your welding parameters
Press and release the trigger to erase
USB overload
024
Disconnect your USB
An internal system error has occurred.
-
Please restart your product
-
The product's memory space is full.
File %s not supported
-
Err %d
Continue anyway?
-
Unable to write to USB stick
If an error code which is not listed appears or your problems persist, contact your distributor.
12
Messages
Solutions
Have your mains supply checked by an authorised person.
Presence of a stray current. Check the cabling of the welding acces-
sories (torch, ground clamp, etc.)
Wait a few minutes for the power source to cool down.
Ensure that the recommended duty cycle for the selected welding
current used is not exceeded.
Ensure that air inlets and outlets are not obstructed.
Switch off the power supply by unplugging the mains connector, and
check that the fan is not blocked.
Check that the trigger on the MIG/MAG torch is not blocked or stuck.
Check the pressure settings on the wire-feeding rollers.
Check that the welding wire is not blocked in the torch liner.
Check the power source settings and installation (welding wire, rol-
lers, gas, torch, etc.)
If the problem persists, update the software (via Planet GYS).
Check the power source settings and installation (welding wire, rol-
lers, gas, torch, etc.)
If the problem persists, update the software (via Planet GYS).
Change the USB stick.
Turn the product off and on again.
If the problem persists, update the software (via Planet GYS)
Delete Jobs to free up internal storage space.
The data on the USB stick is corrupted. Check your data.
Free up some space on the USB key.
If the problem persists, change the USB stick..