Error Codes - GYS TITANIUM 400 AC/DC Manual De Instrucciones

Ocultar thumbs Ver también para TITANIUM 400 AC/DC:
Tabla de contenido

Publicidad

Error codes

The following table shows a non-exhaustive list of messages and error codes that may appear.
Carry out these checks and controls before contacting an authorised GYS technician.
If the user needs to open the product, they must turn off the power supply by unplugging the electrical plug and waiting two minutes
for safety.
Error codes
OVER VOLTAGE FAULT
001
Check the electrical installation
UNDERVOLTAGE FAULT
002
Check the electrical installation
COOLING UNIT FAULT
006
The cooling unit can no longer be detected.
FLOW RATE FAULT
007
Blocked cooling system
WATER LEVEL FAULT
008
Check the water level
COOLING GROUP
009
Thermal protection
GENERATOR
010
Thermal protection
Fan
011
Fan fault
Welding start problem
020
Please check your welding parameters
Press and release the trigger to clear.
USB overload
024
Unplug your USB.
An internal system error has occurred.
-
Please restart your machine
-
Error during motor calibration
-
Error during calibration
-
No more memory space in the machine
Unsupported files %s
-
Err %d
Continue anyway?
-
Unable to save to the USB stick
Number of attempts exceeded.
-
Unlock code required
-
Wrong user code
If an unlisted error code appears or your problems persist, contact your distributor.
Messages
Solutions
Have your electrical installation checked by an authorised person.
Check the connection between the undetected cooling unit and the
power source.
Check the continuity of the coolant flow to the torch.
Check the fuse of the cooling unit.
Fill the cooling unit's tank to the maximum (with coolant ref. 062511)
Wait a few minutes for the cooling unit to cool down.
Take care not to exceed the recommended duty cycle for the welding
current being used.
Ensure that air inlets and outlets are not obstructed.
Wait a few minutes for the power source to cool down.
Ensure that the recommended duty cycle for the welding current used
is not exceeded. Thermal protection Ensure that the air inlets and
outlets are not obstructed.
Installing a dust filter (ref. 046580). Please note that the dust filter
reduces the duty cycle.
Fan Switch off the power supply by unplugging the electrical plug and
check the fan. Ensure that the fan is not blocked.
Check the power source's settings and the machine's installation (filler
wire, rollers, etc.)
If the problem persists, carry out an update (Via Planet GYS).
Change the USB stick.
Restart your machine by turning the machine off and on again.
If the problem persists, carry out update (via Planet GYS)
Recalibrate the motor reel speed (Menu «Calibration»)
Recalibrate the welding cables (Menu «Calibration»)
Delete Jobs to free up the internal storage space.
The data on the USB stick is corrupted.
Free up space on the USB stick.
If the problem persists, change the USB stick.
Enter unlock code: 314159
Wrong user code If the personal code is wrong, enter the correct
code. By default, this code is 0000.
17

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Titanium 230 ac/dc fv

Tabla de contenido