Quick Start; Continuous Operation - Calpeda META Instrucciones De Uso

Ocultar thumbs Ver también para META:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 40
ENGLISH
Before starting the system, read the mèta instruction manual
for installation
1. Set parameter AP01 as defined in
After starting, with the pump fully primed and running
following check.
2 Check that the following conditions are met:
2.1. Open a tap to get half of the flow rate ( 4-5 litres per minute); in these conditions, the
pump must work continuously.
If the pump has an intermittent operation (discontinuous flow) decrease the parameter AP06
by 0,1bar steps as long as the operation is continuous.
2.2. Close the tap at ¼ of the flow rate ( 2 litres per minute); in these conditions, the pump
must work intermittently.
If the pump has a continuous operation (continuous flow) increase the parameter AP06 by
0,1bar steps as long as the operation is intermittent.
3. Once step 2.2 has been verified, check step 2.1 again to ensure that both steps are satisfied
with the same value of parameter AP01.
If errors appear during the procedure, see chap. 12, 13 and 14 of the instruction manual.
META_S_Rev6-s11

QUICK START

(chap.6), startup and operation
½ opened tap
( 4-5 l/min)
¼ opened tap
( 2 l/min)
(chap.8) .
paragraph 8.3.
(see paragraph 8.4), carry out the
Continuous
operation
Intermittent
operation
3 / 80

Publicidad

Tabla de contenido
loading

Tabla de contenido