Program 2
12V
1
(14.7 V / 5.0 A)
To charge 12 V batteries with a
capacity of 20 Ah to 100 Ah under
cold conditions or to charge AGM
batteries.
Press the program selector button
twice to select Program 2.
The
12V
,
3
1
symbols are shown on the LC
display. During the charging pro-
cess, the charging display
flashes. The progress of the charg-
ing process (1-4 bars) will be shown
on the status display
battery is fully charged, the status
display shows
10
ing stops and the device switches to
trickle charging automatically.
The display will show "FUL".
Program 3
12V
2
(14.4 V / 10.0 A)
To charge 12 V batteries with a
capacity of 60 Ah to 200 Ah. To
maintain the charge of 12 V batter-
ies up to 300 Ah.
Press the program selector button
three times to select Program 3.
and
4
6
9
. When the
10
4 bars. The flash-
The
12V
3
are shown on the LC display. During
the charging process, the charging
display
flashes. The progress of
9
the charging process (1-4 bars) will
be shown on the status display
When the battery is fully charged,
the status display shows
The flashing stops and the device
switches to trickle charging automat-
ically. The display will show "FUL".
8
Program 4
12V
2
(14.7 V / 10.0 A)
To charge 12 V batteries with a
capacity of 60 Ah to 200 Ah under
cold conditions or to charge AGM
batteries. To maintain the charge of
12 V batteries up to 300 Ah.
Press the program selector button
four times to select Program 4.
The
12V
,
3
symbols are shown on the LC
display. During the charging pro-
cess, the charging display
flashes. The progress of the charg-
ing process (1-4 bars) will be shown
on the status display
battery is fully charged, the status
display shows
ing stops and the device switches to
trickle charging automatically.
8
The display will show "FUL".
Using the device
and
symbols
5
2
4 bars.
10
and
5
2
9
. When the
10
4 bars. The flash-
10
GB/MT
.
10
8
6
91