Troubleshooting Tips - Haier QPCA08 Instrucciones De Instalación Y Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

TROUBLESHOOTING TIPS

Problem
Possible Causes
Unit does not st art or
Power supply cord is not plugged into an
out let .
operate
Power supply cord has t ripped.
The Power but ton has not been pressed.
There is no power to t he elect rical out let .
A household fuse has blown or a circuit
breaker has t ripped.
The cont rol was programmed for a Time
Delay.
The bat teries in t he remote cont rol are dead. Replace t he bat teries.
The internal water t ank is full.
NOTE: The air condit ioner automat ically
t urns off, and t he Water Full indicator
illuminates to alert you of t his condit ion.
Remote cont rol is not
Bat teries are dead.
working
Bat teries are inst alled incorrect ly.
The room temperat ure is hot .
Air condit ioner is
working but t he room
NOTE: On ext remely hot and humid days,t he
is not cooling.
air condit ioner will t ake longer to cool t he
room.
The cont rol is set incorrect ly to Fan or Dehum
mode.
Airflow is rest ricted.
Temperat ure set too high.
Air filters are dirt y or rest ricted.
Air condit ioner inst alled incorrect ly
Doors and windows are open.
49- 5000543 Rev. 2
Solut ion
Plug t he power cord into a grounded 3 prong out let .
Press and release t he RESET but ton on t he power
supply cord.
Press t he Power but ton on t he Cont rol Panel or
Remote Cont rol to t urn ON t he air condit ioner.
Plug a working lamp into t he out let to check for
power.
Replace t he fuse or reset t he circuit breaker.
Cancel t he Time Delay. See "Cont rol Panel."
Empt y t he water t ank. See "Air Condit ioner
Care."
Replace t he bat teries.
Make sure t he bat teries are inserted in t he correct
posit ion.
Allow t ime for t he room to cool when you first t urn
on t he unit .
Make sure t he air condit ioner has an adequate
BTU rat ing for t he size of t he room being cooled.
Set t he Mode to Cool and t he Fan Speed to High.
Remove any obst acles to t he airflow and redirect
airflow for uniform cooling.
Lower t he set temperat ure.
Clean t he air filter. See "Air Condit ioner Care."
Check t he exhaust hose and window panel for
proper inst allat ion.
Close t he doors and windows to t he room being
cooled to prevent cooled air from escaping.
15

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido