Specifications:
radio controlled clock
indoor temperature: 0 °C to +50 °C
outdoor temperature: -20 °C to +60 °C
temperature resolution: 0.1 °C
temperature measurement accuracy: ±1 °C (for 0 °C to +40 °C range), otherwise ±2 °C
indoor and outdoor humidity: 20 to 95 % RH
humidity resolution: 1 % RH
humidity measurement accuracy: +/-5 % for 30 % to 60 % range
barometric pressure measurement range: 850 hPa to 1,050 hPa
wireless sensor: transmission frequency 433 MHz, 10 mW e.r.p. max.
radio signal range: up to 50 m in open area
number of sensors for connection: max. 1
main station power supply: 3× 1.5 V AAA batteries (not included)
adapter power supply: AC 230 V/DC 5 V/1 A (included)
sensor power supply: 2× 1.5 V AAA batteries (not included)
dimensions and weight without batteries:
main station: 27 × 250 × 95 mm, 338 g
sensor: 21 × 60 × 100 mm, 54 g
Weather Station Description
Main panel (see Fig. 1)
1 – screen illumination mode; 2 – weather forecast; 3 – pressure history; 4 – pressure trend indicator;
5 – pressure value; 6 – DST – daylight savings time; 7 – time; 8 – alarm activation; 9 – DCF signal
reception; 10 – day of the week; 11 – month; 12 – date; 13 – morning/afternoon (AM/PM); 14 – max./
min. outdoor temperature and humidity; 15 – outdoor temperature; 16 – outdoor temperature trend
indicator; 17 – low battery in the outdoor sensor icon; 18 – outdoor humidity; 19 – signal reception
from outdoor sensor; 20 – temperature alert; 21 – outdoor sensor icon; 22 – indoor temperature;
23 – indoor humidity; 24 – comfort icon; 25 – indoor temperature and humidity icon; 26 – low battery
in the station icon; 27 – indoor temperature trend indicator; 28 – min./max. indoor temperature and
humidity; 29 – holder; 30 – battery cover; 31 – battery compartment.
Back (see Fig. 2)
Button
Button press
1. Snooze function activation/
(A) SNOOZE
deactivation
LIGHT
2. screen illumination
(B) MODE
time display mode / Alarm 1 / Alarm 2 basic station settings
show MAX/MIN temperature and
(C) UP " "
humidity; one step forward in settings
set °C/°F temperature unit; one step
(D) DOWN " "
back in settings; activate/deactivate
alarm
(E) HISTORY
show air pressure history
(F) SEARCH
(G) DC jack
+/-8 % spread at 20 % to 29 % / 61 % to 95 %
4
Hold button for 3 seconds
set illumination mode A, B or C
erase MAX/MIN temperature and
humidity data.
set outdoor temperature limit
set altitude
pair with sensor