PROCESS SETTINGS
Settings
Rutile
Electrode type
Basic
Anti-Sticking
ON-OFF
Access to some of the welding parameters depends on the selected display mode: Settings/Display mode: Easy or Expert. Refer to the HMI ma-
nual.
WELDING PROCESSES
• Standard
This standard MMA welding mode is suitable for most welding applications. It enables welding with all types of coated, rutile, basic and cellulosic
electrodes, as well as on all materials: steel, stainless steel and cast iron.
• Pulse
The pulsed MMA welding mode is suitable for upright (PF) applications. The pulsed setting keeps the weld pool cold while promoting material transfer.
Without pulsing, vertical upward welding requires a 'Christmas tree' movement, i.e. a difficult triangular movement. Thanks to Pulsed MMA welding,
it is no longer necessary to perform this movement. Depending on the thickness of your workpiece, a straight upward movement should suffice.
However, if you want to enlarge your weld pool, a simple sideways movement similar to downheld welding is sufficient.. In this case, you can set the
frequency of your pulsed current on the display screen. This method offers greater control of the vertical welding operation.
CHOOSING COATED ELECTRODES
• Rutile electrodes: very easy to use in any position.
• Basic electrodes: it can be used in all positions and is suitable for safety work due to its increased mechanical properties.
CONFIGURING THE SETTINGS
Arc Force
Welding current
Duration of Hot Start
Pulse
frequency
Percentage Hot Start
Percentage I cold
Cold weather
Access to some of the welding parameters depends on the selected display mode: Settings/Display mode: Easy or Expert. Refer to the HMI ma-
nual.
ADJUSTING THE WELDING INTENSITY
The following settings correspond to the applicable current range depending on the type and diameter of the electrode used. These ranges are quite
large as they depend on the usage and the welding position.
electrode Ø (mm)
1.6
2.0
2.5
3.15
4.0
5
6.3
32
Translation of the original
instructions
Welding processes
Settings
Standard
Units
Arc Force is an overcurrent administered to prevent sticking when the electrode or weld bead touches the weld
pool.
A
The welding current is determined by the type of electrode chosen (see electrode packaging).
Hot Start is an overcurrent at the ignition stage which prevents the electrode from sticking to the workpiece. The
s
intensity (% of welding current) and the time (seconds) can be programmed.
Hz
PULSE mode's PULSING frequency.
Hot Start is an overcurrent at the ignition stage which prevents the electrode from sticking to the workpiece. The
%
intensity (% of welding current) and the time (seconds) can be programmed.
%
s
Rutile E6013 (A)
30-60
50-70
60-100
80-150
100-200
150-290
200-385
Pulsed
The type of electrode determines the settings in order to optimise its
weldability depending on the type of electrode used.
The anti-stick feature is recommended to safely remove the electrode in
the event of it sticking to the workpiece (the current is cut off automati-
cally).
Basic E7018 (A)
30-55
50-80
80-110
90-140
125-210
200-260
220-340