Technical Data; Compatibility With Inverters - Fronius Rapid Shutdown Box - Duo Instrucciones De Instalación

Ocultar thumbs Ver también para Rapid Shutdown Box - Duo:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Technical Data

Max. voltage
Start voltage
Max. input current
Power supply
Self-consumption during operation
Permissible operating temperature
Permissible humidity
Max. altitude
Max. number of Controlled circuits
(per NEC)
Enclosure type
Device dimensions h x w x d
Shipping dimensions h x w x d
Shipping weight
Standards and regulations
Compatibility
Inverter (SnapINverter series)
with Inverters
Fronius Galvo 1.5-1 208-240
Fronius Galvo 2.0-1 208-240
Fronius Galvo 2.5-1 208-240
Fronius Galvo 3.1-1 208-240
Fronius Primo 3.8-1 208-240
Fronius Primo 5.0-1 208-240
Fronius Primo 6.0-1 208-240
Fronius Primo 7.6-1 208-240
Fronius Primo 8.2-1 208-240
Fronius Primo 10.0-1 208-240 *)
RSB Duo
RSB Quattro
600 V DC
80 V DC
25 A
DC (from the PV array)
2 W
-40° F to +149° F (-40° C to +65° C)
0 - 100 % (not condensing)
13,123 ft. (4000 m)
1
NEMA 4X
11.26 x 9.7 x 2.62
13.82x11.54x2.62
in.
(286 x 246,5 x
(351 x 293 x 66,6
66,6 mm)
13 x 12 x 5.9 in.
13.78x11.81x6.1in
(330x305x150
mm)
(350x300x155
5.95 lbs. (2,7 kg)
8.16 lbs. (3,7 kg)
UL1741; LTR AE-004-2015; FCC15
Class B
Rapid Shutdown Box - Duo / Quat-
tro
25 A / 25 A
2
in.
mm)
.
mm)
7