Installing and connecting the cooling device
6.3
Connecting the cooling device
For the electrical connection you also need the wiring diagram (5, page 4).
No. in 5,
Meaning
page 4
1
Electronic terminal rail
2
Compressor
3
DC fan (if present)
4
Temperature controller
Cable colours:
No. in 5,
Meaning
page 4
bl
blue
br
brown
rt
red
sw
black
Connecting to a battery
The cooling device can be operated with a 12 V to 24 V DC voltage supply.
To avoid voltage loss and therefore a drop in performance, the
cable should be kept as short as possible and should not be
interrupted if this is possible.
For this reason avoid additional switches, plugs or power strips.
➤ Determine the required cross section of the cable in relation to the cable
length according to 6, page 4.
Key for 6, page 4
Co-ordinate axis
l
∅
Caution!
Make sure that the polarity is correct.
24
Meaning
Cable length
Cable cross section
CB-36, CB-40, RHD-50
Unit
m
mm²