12. MOUNTING THE RACK HANGER
Parts Required:
1
x
Rack Hanger (#10)
Installation:
•
Secure the Rack Hanger to the back panel of the Main Barrel using
the pre-assembly two screws. Cooking Racks can be hung on the Rack
Hanger while not in use.
13. PLACING THE GREASE BUCKET
Parts Required:
1
x
Grease Bucket (#16)
Installation:
•
Place the Grease bucket on the spout hook on the end of the Main
Barrel. Ensure it is level to avoid grease spills.
•
The unit is now completely assembled.
14. CONNECTING TO A POWER SOURCE
•
STANDARD OUTLET
This appliance requires 110-120 volt, 60 Hz, 315 w. It must be a 3-prong
grounded plug. Ensure grounded end is not broken off before use. The
control uses a 110-120 volt, fast-blow fuse to protect the board from
the ignitor.
•
GFCI OUTLETS
This appliance will work on most GFCI outlets, with a recommended
size of 15 amp service. If your GFCI outlet is highly sensitive to power
surges, it will likely trip during the start-up phase of operation. During
the start-up phase, the ignitor draws 200-700 watts of electricity
which can be too much power for a GFCI outlet to handle. Each time it
trips, it increases in sensitivity. If the GFCI keeps tripping, replace the
outlet or change to a non-GFCI outlet.
•
ON THE ROAD
Disconnect the ignitor from the main wiring harness. Use the manual
start-up procedure. A Pit Boss® unit can operate using a 12 volt,
100 watt inverter plugged into your automobile outlet. To use the
automatic ignitor, it is recommended to use a minimum of a 1000
watt inverter.
IMPORTANT: Disconnect unit from power source when not in use.
12
12
13
16
14
10