Earthing Protection
This section outlines the information for installation
of Wallbox Pulsar Plus in the UK region.
Part Numbers Affected: PLP1-X-X-2-F-XXX-A
In the UK region, the PME system with an incoming earthing point
is widely used by residential and business electricity consumers. 
The RCCB does not provide protection against open circuit PME faults,
so touch voltage hazards could occur without triggering a disconnection
of the mains electricity supply to the building.
Wiring Diagram
To follow and be compliant with
the regulations specified by IET
in clause 722.411.4.1(iv), Wallbox
L1 L2 L3 N PE
Pulsar Plus uses a technology
that enables you to directly connect
your charger to a PME supply.
The Wallbox Pulsar Plus UK
charger now includes a safety
monitoring system to detect
L
PE
N
potential earth-neutral faults.
If faults are detected in the circuit,
the charge cycle ends thus isolating
the vehicle from the power supply.
This removes the risk of touching
the vehicle and a potential shock
if earth-neutral fault is present.