EN-2
1.4

Safety Precautions

1.4.1 User

OHAUS centrifuges are intended exclusively for indoor use and for use by qualified personnel. This device may
only be operated by trained specialist stuff. They must have carefully read the operating manual and be familiar
with the function of the device.

1.4.2 Rotor and accessories

Only OHAUS original rotors and accessories shall be used. Any other use or intended use is considered improper.
OHAUS is not liable for damage resulting from improper use.
CAUTION:
Read all safety warnings before installing, making connections, or servicing this equipment. Failure to
comply with these warnings could result in personal injury and/or property
damage. Retain instructions for future reference.

1.4.3 Measures for your protection

WARNING: Never work in an environment subject to explosion hazards! The housing of the instrument
is not gas tight. (Explosion hazard due to spark formation, corrosion caused by
WARNING: When using chemicals and solvents, comply with the instructions of the producer and the
general lab safety rules.
WARNING: The centrifuge is not sealed. Use suitable protection measures when using the centrifuge
for infectious and pathogenic samples. Follow appropriate safety precautions when handling these
samples.

1.4.4 Exclude the following environmental influences

 Powerful vibrations
 Direct sunlight
 Atmospheric humidity greater than 80%
 Corrosive gases present
 Temperatures below 2 ° C and above 35 ° C
 Powerful electric or magnetic fields:
WARNING:
Electrical shock hazards exist within the housing. The housing should only be opened by authorized
and qualified
personnel.
Remove all power connections to the unit before opening.

1.4.5 Measures for operational safety

 Do not unscrew the two halves of the housing
 Dry off any liquid spills immediately! The instrument is not watertight
 Verify that the equipment's input voltage range and plug type are compatible with the local power supply.
 Only connect the power cord to a properly grounded power receptacle.
 Only use a power cord with a rating that exceeds the specifications on the equipment label.
 Do not position the equipment such that it is difficult to disconnect the power cord from the power receptacle.
 Make sure that the power cord does not pose a potential obstacle or tripping hazard.
 The equipment is for indoor use only. Use the equipment only in dry locations.
 Use only approved accessories.
 Operate the equipment only under ambient conditions specified in these instructions.
 Disconnect the equipment from the power supply when cleaning.
 Do not operate the equipment in hazardous or unstable environments.
 Service should only be performed by authorized personnel.
TM
Frontier
Centrifuge FC5706
the ingress of gases)