Descargar Imprimir esta página

Altrad Belle PCX 13/40E+ Manual Del Operador página 27

Publicidad

Idiomas disponibles

Idiomas disponibles

DRIVE BELT
of the belt, as near central between the power unit drive and vibrator pulley. The belt should
If the belt tension requires adjustment, remove the belt. Loosen the four power unit mounting
bolts (Highlighted Grey in the adjacent diagram (1 bolt is hidden by the power unit)
second time. If the belt tension is correct, retighten the power unit mounting bolts. If the Belt
remains loose, replace the belt.
VIBRATOR UNIT
Place the machine safely on stable, level ground. Remove the plug complete with seal, check that the oil level reaches the bottom
Plug
Seal
Regular
Level
Lower part of the screw thread
CLEANING
Keeping the machine clean is an integral part of the service and maintenance program. The build-up of mud, dirt and debris could
situations.
WARNING
ALWAYS clean the machine using compressed air and wipe the battery pack clean with a dry, clean cloth.
After the cleaning process check that all cables, hoses and fasteners are in place and secure. Replace any if necessary.
Also ENSURE that all safety / warning decals are present in their correct locations. Replace any if necessary.
Service and Maintenance
NEVER use a hose or pressure washer to spray water on the machine while cleaning it. Water entering
the components may cause a malfunction and/or injury.
Component
Vibrator
27
Oil Type
Turbine Oil 32
GB
Quantity
0.3 Litres

Publicidad