CAUTION!
The air speed in the vacuum hose must not be less than
20 m/s.
Condition indicated by the vacuum gauge pointer in the
green zone (3).
CAUTION!
All machines can be used only with hoses whose
diameters comply with the specifications in the
"Technical Data" table.
CAUTION!
Consult the "Troubleshooting" chapter if faults occur.
At the end of a cleaning session
■
Turn off the machine and remove the plug from the socket.
■
Wind up the connection cable.
■
Empty the container and clean the machine as described
in the "Maintenance, cleaning and decontamination"
paragraph.
■
Wash the container with clean water if aggressive
substances have been vacuumed.
■
Store the machine in a dry place, out of reach of
unauthorised people.
■
Lock the castor brakes.
■
During transport and when not using the machine, close
the vacuum inlet with the relevant plug (if equipped).
11
T40PLUS - T40WPLUS
C380
GB