T40PLUS - T40WPLUS
Problem
The vacuum cleaner suddenly stops
Dust leaks from the vacuum cleaner
The vacuum cleaner blows instead of
vacuuming
Electrostatic current on the vacuum
cleaner
GB
C380
Troubleshooting
Cause
Clogged primary filter
Clogged vacuum hose
Circuit breaker activation
The filter is torn
Inadequate filter
Incorrect connection to the electrical mains
Missing or inefficient grounding
20
Remedy
Shake the filter. Replace it if necessary
Check the vacuum hose and clean it.
Check the setting.
Check the motor electrical input. Contact
an authorised after-sales service centre if
necessary.
Replace it with another of identical type.
Replace it with another of a suitable category
and check.
Ask for assistance from qualified personnel to
perform the correct phase connection.
See page 8, Starting up chapter
Check all ground connections. Especially check
the inlet.