Accuracy (cont'd)
All Models (cont'd)
AC Current
Range (50 Hz to 400 Hz)
600.0 µA
6000 µA
60.00 mA
600.0 mA
6.000 A
8.00 A*
Accuracies for DM-510A are specified from 5% to 100% of range
* 8 A continuous, > 8 A to 15 A for 30 second max with 5 minutes cool down interval
DC Current
Range
600.0 µA
6000 µA
60.00 mA
600.0 mA
6.000 A
8.00 A*
* 8 A continuous, > 8 A to 15 A for 30 second max with 5 minutes cool down interval
Frequency —Hz (Line) at ACV, DCV, Current, AutoCheck™ Mode
Function
6 V
60 V
600 V
1000 V
600 µA
6000 µA
60 mA
600 mA
6 A
10 A
18
Accuracy
± (1.0% + 0.3 µA)
± (1.0% + 3 µA)
± (1.0% + 0.03 mA)
± (1.0% + 0.3 mA)
± (1.2% + 0.006 A)
± (1.8% + 0.06 A)
Accuracy
± (0.5% +0.5 µA)
± (0.5% + 3 µA)
± (0.5% + 0.05 mA)
± (0.5% + 0.3 mA)
± (1.2% + 0.006 A)
± (1.8% + 0.06 A)
Sensitivity (Sine RMS)
0.4 V
4 V
40 V
400 V
40 µA
400 µA
4 mA
40 mA
1 A
6 A
Burden Voltage (typical)
0.1 mV/µA
1.7 mV/mA
0.03 V/A
Burden Voltage (typical)
0.1 mV/µA
1.7 mV/mA
0.03 V/A
Range
10 Hz to 10 kHz
10 Hz to 50 kHz
10 Hz to 50 kHz
45 Hz to 1 kHz
10 Hz to 10 kHz
10 Hz to 10 kHz
10 Hz to 10 kHz
10 Hz to 10 kHz
10 Hz to 1 kHz
10 Hz to 1 kHz