Greenlee DM-200A Manual De Instrucciones página 19

Multímetros digitales
Ocultar thumbs Ver también para DM-200A:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Accuracy (cont'd)
All Models (cont'd)
Accuracy of Frequency Ranges
Display Range
9.999 Hz
99.99 Hz
999.9 Hz
9999 Hz
99.99 kHz
999.9 kHz
Frequency—Logic Level Hz (mV Function)
Range
5.0 Hz to 9.999 Hz
99.99 Hz
999.9 Hz
9999 Hz
99.99 kHz
100.0 kHz to 500.0 kHz
500.0 kHz to 999.9 kHz
Non-contact Electric Field Detection (EF)
Typical Voltage
10 V to 36 V
23 V to 83 V
59 V to 165 V
124 V to 330 V
250 V to 1000 V
* Bar graph indication and tone are proportional to signal strength
Accuracy
± (0.03% + 0.003 Hz)
± (0.03% + 0.03 Hz)
± (0.03% + 0.3 Hz)
± (0.03% + 3 Hz)
± (0.03% + 0.03 kHz)
± (0.03% + 0.3 kHz)
Accuracy
± (0.03% + 0.002 Hz)
± (0.03% + 0.02 Hz)
± (0.03% + 0.2 Hz)
± (0.03% + 2 Hz)
± (0.03% + 0.02 kHz)
± (0.03% + 0.2 kHz)
± (0.03% + 0.2 kHz)
Bar Graph Indication*
– –
– – –
– – – –
– – – – –
DM-200A • DM-210A • DM-510A
Sensitivity
(square wave)
3 V peak
5 V peak
Frequency Range
50 Hz to 60 Hz