Descargar Imprimir esta página

Kärcher SB V 1 Eco Manual Del Usuario página 27

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 68
Device installation
Only for authorised technicians!
!
Electrical connection
For connection values, see technical
data and type plate.
The electrical connections must be
done by an electrician according to IEC
60364-1.
The voltage indicated on the type plate
must correspond to the voltage of the
electrical source.
Preparing the installation place
For proper installation of the appliance,
please take care of the following points
There must be a horizontal, even sur-
face with minimum dimensions of
900 mm x 900 mm.
Power supply according to measure-
ment chart (X), see Appendix.
Caution
Select the installation site in such a way
that the exhaust air cover and the air supply
channel are always kept open to protect the
machine against over-heating.
Drill 3 fastening holes d=12 mm, 43 mm
depth according to measurements
chart.
Install the device and align it
Open device door.
Remove transport lock.
Remove vacuum cleaner and suction
hose from the appliance casing.
Caution
Risk of injury due to machine toppling over.
The machine must be installed and fas-
tened with screws on a firm, solid base.
Fasten the appliance using the enclosed
fasteners:
Insert the dowel (5) in the drilled holes.
Place the appliance at the proposed
site. Guide the cable for the electrical
connection through the opening in the
base of the appliance.
Insert covers (1) in the base plate of the
appliance (4).
Insert the discs (2) as shown in the
drawing.
Insert the screws (3) and tighten it with
a tightening torque of 20 Nm.
– 12
EN
27

Publicidad

loading